HI-SUN

Product Details​


  • OFOC-001-SC
    OFOC-001-SC
    OFOC-001-SC
    ❤ 收藏
  • OFOC-001-SC

    External dimensions of outdoor adapters:Φ22×45.6 mm;

    External Dimension of outdoor protective pipe:Φ25×65 mm;


    重量:0.000KG
    • 数量:
商品描述

External dimensions of outdoor adapters:Φ22×45.6 mm;

External Dimension of outdoor protective pipe:Φ25×65 mm;






                                       OFOC-001-SC  Outdoor adapter performance    

Item

Outdoor Simplex Adapter

Max. Insertion loss

≤0.2dB

Average Insertion loss

≤0.1dB

Endurance

500次

Adapter mated with Dust cap1and Dust cap2 Ingress protection

IP65 (IEC60529

Other parameters meet standard

IEC61754-4-2003,YD/T 2341.1-2011,IEC 61753-1


Test Method for insertion loss: Reference Standard IEC-61300-3-4




Reliability testing

Parameter

Test Method

Conditions

Requirements

VIBRATION

IEC 61300-2-1

10 Hz – 55 Hz

15 sweeps (10 Hz – 55 Hz – 10 Hz)

octave/minute

axes

0.75 mm amplitude

during and after the test

IL: D ai ≤0.20 dB

RL:≥ 60 dB

RESISTANCE COUPLING MECHANISM

IEC 61300-2-6, test with SC/APC connector and A-SA-COSAC adapter

80N, 5N/S, 0.2m of connector end, 60s

during and after the test

IL: D ai ≤0.20 dB

RL:≥ 60 dB

FALL

IEC 61300-2-6(method B)

1m, 10 times

during and after the test

IL: D ai ≤0.20 dB

RL: ≥ 60 dB

STATIC LATERAL CHARGE TEST

IEC 61300-2-42

50N

application point: 0.5 m from the end of the connector

duration: 1 hour

during and after the test

IL: D ai ≤0.20 dB

RL: ≥ 60 dB

COLD

IEC 61300-2-17

Temperature = -25ºC

Duration: 96 h.

Conditioning and recovery method: 2 h.

25ºC 60% RH

during and after the test

IL: D ai≤ 0.20 dB

RL: ≥ 60 dB

DRY HEAT

IEC 61300-2-18

Temperature = +75ºC

Duration: 96 h.

Conditioning and recovery method: 2 h.

25ºC 60% RH

during and after the test

IL: D ai≤ 0.20 dB

RL:≥ 60 dB

DUST

IEC 61300-2-27

Particle size

d < 150 mm

environmental conditions:

+35ºC + 2ºC, 60% + 10% RH

time: 24 h.

during and after the test

IL: D ai < 0.20 dB

RL (SPC/APC): > 60 dB

The sample must not have deteriorated due to the test (corrosion, etc.)

CHANGE IN TEMPERATURE

IEC 61300-2-22

High temperature = +70ºC

Low temperature = -25ºC

Duration at extreme temps.: 1 h.

Temperature change speed: 1ºC/min

Cycles: 12

Conditioning and recovery method: 2 h.

25ºC, 60% RH

during and after the test

IL: D ai ≤ 0.20 dB

RL:≥ 60 dB

HUMIDITY

IEC 61300-2-19

Temperature = +40ºC

RH = 93%

Time: 96 h.

Conditioning and recovery method: 2 h.

25ºC 60% RH

during and after the test

IL: D ai ≤0.20 dB

RL: ≥ 60 dB

SALINE MIST

IEC 61300-2-26

Solution: 5% NaCl (Sodium Chloride)

Ph 6.5-7.2

temperature = +35ºC

Time: 96 h.

Conditioning and recovery method: 2 h.

25ºC 60% RH

during and after the test

IL: D ai ≤ 0.20 dB

RL: ≥ 60 dB

The sample must not have deteriorated due to the test (corrosion, etc.)

IP65

IEC 60529

 

No water or dust get into the adapter

Other parameters meet standard

 

IEC61754-4, YD/T 2341.1-2011,IEC61753-1

 





SC Outdoor adapter RoHS Environmental Requirements


ROHS agreement: □ Huawei Std; ■ Compliant; □ Exempted; □ Exempted Network
WEEE and CE compliant





Working Environment

Working temperature : -25℃~70℃
Working humidity: ≤95%
Installation temperature: -5℃~50℃
Storage Temperature: -40℃~70℃





     
  • 购买人 会员级别 数量 属性 购买时间
  • 商品满意度 :
暂无评价信息