Product Details
External dimensions of outdoor adapters:Φ22×45.6 mm;
External Dimension of outdoor protective pipe:Φ25×65 mm;
Item |
Outdoor Simplex Adapter |
Max. Insertion loss |
≤0.2dB |
Average Insertion loss |
≤0.1dB |
Endurance |
500次 |
Adapter mated with Dust cap1and Dust cap2 Ingress protection |
IP65 (IEC60529 |
Other parameters meet standard |
IEC61754-4-2003,YD/T 2341.1-2011,IEC 61753-1 |
Parameter |
Test Method |
Conditions |
Requirements |
VIBRATION |
IEC 61300-2-1 |
10 Hz – 55 Hz 15 sweeps (10 Hz – 55 Hz – 10 Hz) octave/minute axes 0.75 mm amplitude |
during and after the test IL: D ai ≤0.20 dB RL:≥ 60 dB |
RESISTANCE COUPLING MECHANISM |
IEC 61300-2-6, test with SC/APC connector and A-SA-COSAC adapter |
80N, 5N/S, 0.2m of connector end, 60s |
during and after the test IL: D ai ≤0.20 dB RL:≥ 60 dB |
FALL |
IEC 61300-2-6(method B) |
1m, 10 times |
during and after the test IL: D ai ≤0.20 dB RL: ≥ 60 dB |
STATIC LATERAL CHARGE TEST |
IEC 61300-2-42 |
50N application point: 0.5 m from the end of the connector duration: 1 hour |
during and after the test IL: D ai ≤0.20 dB RL: ≥ 60 dB |
COLD |
IEC 61300-2-17 |
Temperature = -25ºC Duration: 96 h. Conditioning and recovery method: 2 h. 25ºC 60% RH |
during and after the test IL: D ai≤ 0.20 dB RL: ≥ 60 dB |
DRY HEAT |
IEC 61300-2-18 |
Temperature = +75ºC Duration: 96 h. Conditioning and recovery method: 2 h. 25ºC 60% RH |
during and after the test IL: D ai≤ 0.20 dB RL:≥ 60 dB |
DUST |
IEC 61300-2-27 |
Particle size d < 150 mm environmental conditions: +35ºC + 2ºC, 60% + 10% RH time: 24 h. |
during and after the test IL: D ai < 0.20 dB RL (SPC/APC): > 60 dB The sample must not have deteriorated due to the test (corrosion, etc.) |
CHANGE IN TEMPERATURE |
IEC 61300-2-22 |
High temperature = +70ºC Low temperature = -25ºC Duration at extreme temps.: 1 h. Temperature change speed: 1ºC/min Cycles: 12 Conditioning and recovery method: 2 h. 25ºC, 60% RH |
during and after the test IL: D ai ≤ 0.20 dB RL:≥ 60 dB |
HUMIDITY |
IEC 61300-2-19 |
Temperature = +40ºC RH = 93% Time: 96 h. Conditioning and recovery method: 2 h. 25ºC 60% RH |
during and after the test IL: D ai ≤0.20 dB RL: ≥ 60 dB |
SALINE MIST |
IEC 61300-2-26 |
Solution: 5% NaCl (Sodium Chloride) Ph 6.5-7.2 temperature = +35ºC Time: 96 h. Conditioning and recovery method: 2 h. 25ºC 60% RH |
during and after the test IL: D ai ≤ 0.20 dB RL: ≥ 60 dB The sample must not have deteriorated due to the test (corrosion, etc.) |
IP65 |
IEC 60529 |
|
No water or dust get into the adapter |
Other parameters meet standard |
|
IEC61754-4, YD/T 2341.1-2011,IEC61753-1 |
|